NEW QUESTION 23
Which are two benefits of integrating Cisco UCS C-series servers with Cisco UCS Manager? (Choose two ) Cisco UCS Manager provides the ability to automatically update C-series firmware and device drivers from a single global interface.
- A. Cisco UCS Manager can automatically power on and off servers to scale elastically according to application performance demands
- B. Cisco UCS Manager uses service profiles and resource pools to allow the deployment of multiple servers with a single common template
- C. Cisco UCS Manager provides the ability to manage C-series in multiple physical domains from a single global interface
- D. Cisco UCS Manager is able to act as a common centralized management platform for both blade and rack servers in a single domain.
Answer: D
NEW QUESTION 24
When troubleshooting a LAN connectivity issue, you notice a failed uplink from the Cisco UCS Fabric Interconnects to the upstream LAN switch. What two could be causing the issue? (Choose two )
- A. A port channel mismatch between the Fabric Interconnects and the upstream LAN switch
- B. A SFP Type mismatch between the Fabric Interconnects and the upstream LAN switch
- C. A port speed configuration mismatch between the Fabric Interconnects and the upstream LAN switch
- D. Misconfigured QoS parameters on the failed uplink
- E. Misconfigured VLAN on the failed uplink
Answer: A,D
NEW QUESTION 25
What is the next step after performing a UCS firmware upgrade, and downloading the latest drivers both for your RAID Controller and your Fibre Channel HBA?
Check the HCL
- A. No Drivers are needed in a UCS environment
- B. Test device driver compatibility
- C. Apply the device driver update to the devices
- D. No need to do anything Drivers are automatically installed for you
Answer: B
NEW QUESTION 26
Which statement regarding the UCS C-senes connectivity modes best describes connectivity options in a UCS Manager integrated environment?
- A. All UCS C-series servers in a single UCS Manager domain must share the same connectivity model
- B. UCS C-series servers may be connected with or without the use of Fabric Extenders (FEX) in environments running UCS Manager Software Release 2 2 or later
- C. UCS C-series servers must be connected to Fabric Interconnects using Fabric Extenders (FEX)
- D. UCS C-series servers may be connected to multiple UCS Manager domains at the same time
Answer: B
NEW QUESTION 27
Which statement is true regarding the UCS Manager GUI is showing "Overall Status Unassociated" in the General tab for a C-series server?
- A. The server is not properly connected
- B. The server does not have a service profile assigned, but has been discovered by UCS Manager
- C. The server has been properly connected, but has not been discovered by UCS Manager
- D. The server has a service profile assigned, but has connectivity issues with UCS Manager
Answer: A
NEW QUESTION 28
What is the likely cause of an intermittent SAN Boot fails?
- A. LUN ID Mismatch
- B. FCoE used instead of FC
- C. Misconfigured SAN boot target in the boot policy of the service profile
- D. Wrong boot order in the service profile
Answer: C
NEW QUESTION 29
The UCS Chassis Discovery Policy has been set to four and a new chassis is connected with two links What is the resulting chassis recognition action?
- A. The chassis will be recognized but only one of the links will be active.
- B. The chassis will be recognized and both links will be active
- C. The Chassis Discovery Policy will automatically reset to two links, since it always tracks the physical connections
- D. The chassis will not be recognized
Answer: D
NEW QUESTION 30
Which command sequence is required to reset Cisco Integrated Management Controller (IMC) of a Cisco UCS Server?
- A. scope cimc | reset | validate
- B. scope cimc | reset | commit-buffer
- C. connect cimc | reset | validate
- D. connect cimc | reset | commit
Answer: B
NEW QUESTION 31
An overvoltage condition has occurred on a UCS server However the Cisco IMC System Event Log (SEL) file is full What is the resulting fault logging action?
- A. The overvoltage condition event will not be recorded in the SEL.
- B. The SEL is not used to record server related events, such as overvoltage conditions.
- C. The oldest entry in the SEL will be overwritten by the overvoltage condition event
- D. The newest entry in the SEL will be overwritten by the overvoltage condition event.
Answer: A
NEW QUESTION 32
What are three possible causes of service profile association failure due to iSCSI configuration issue? (Choose three )
- A. Misconfigured iSCSI parameters
- B. Misconfigured LUN. LUN masking
- C. Wrong WWNN
- D. iSCSI Target out of configured range of services
- E. Improperly assigned iSCSI Class of Service
- F. Inappropriate network configuration
Answer: A,D,F
NEW QUESTION 33
A new UCS dual fabric cluster is being configured with a single chassis. The administrator notices that the cluster is not in High Availability (HA) mode. What is the possible cause?
- A. The UCS-FI-HA license has not been activated in UCS Manager
- B. The links to the chassis are not enabled
- C. The HA plugin has not been installed in UCS Manager
- D. No uplinks are active into the data center.
Answer: C
NEW QUESTION 34
Which two statements describes connecting the IO Modules in the UCS chassis to the Fabric interconnects? (Choose two )
- A. Connect Fl-A to the IOM A of each chassis
- B. Connect Fl-B to the IOM A of each chassis
- C. Connect Fl-A to the IOM B of each chassis
- D. Connect Fl-B to the IOM B of each chassis
- E. Connect Fl-B to IOM A and IOM B in each chassis
- F. Connect Fl-A to IOM A and IOM B in each chassis
Answer: A,C,D
NEW QUESTION 35
Which statement best describes managing Cisco UCS servers using NX-OS CLI on the Fabric Interconnects?
- A. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the servers and Fabric Interconnects
- B. The NX-OS CLI on the Fabric Interconnects allows you to manage QoS parameters on the Fabric Interconnects and an upstream LAN switch
- C. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
- D. The NX-OS CLI on the Fabric Interconnects allows you to view, but not change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
Answer: C
NEW QUESTION 36
You are experiencing intermittent connectivity issues on one specific Cisco UCS server Some applications work, while other do not transfer data You suspect jumbo frames limitations Which two places do you check the jumbo frame settings? (Choose two )
- A. Check the fibre channel port configuration for jumbo frame configuration
- B. Check server's service profile and/or service profile template
- C. Check server's individual vNICs and/or vHBAs properties
- D. Check server's QoS System Class
- E. Check upstream switch ports frame size configuration
Answer: D,E
NEW QUESTION 37
Which are two Application Gateways primary roles? (Choose two )
- A. Automate updates to the XML Database
- B. Manage configuration changes made with UCS Manager
- C. Communicate with virtual machines and report health and state
- D. Communicate with end points and report their health and state
- E. Manage configuration changes during FSM transitions
Answer: A,E
NEW QUESTION 38
What occurs that causes a Split Brain Issue with Fabric Interconnects?
- A. Both cluster links fail
- B. The subordinate Fabric Interconnect detects heartbeat failure and declares itself primary
- C. Manage configuration changes made with UCS Manager
- D. A quorum tie occurs that must be resolved by the SEEPROM
Answer: B
NEW QUESTION 39
......
Prepare Top Cisco 500-920 Exam Audio Study Guide Practice Questions Edition: https://itcert-online.newpassleader.com/Cisco/500-920-exam-preparation-materials.html